KingCoat CT100®
Heavy duty solvent free coal tar modified epoxy based flooring system
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Compressive strength BS 6319-2
- ≥ 45 MPa @ 7 days
- Flexural strength EN 13892-2
- ≥ 25 MPa @ 7 days
- Tensile strength BS 6319-7
- ≥ 8 MPa @ 7 days
- Specific gravity
- 1.75 ± 0.05
Overview
KingCoat CT100 is a heavy duty solvent free coal tar modified epoxy flooring system. The product comprises of a base, hardener and graded filler, which when mixed form a fluid, homogenous slurry. After spreading KingCoat CT100 slurry and while still wet, hard wearing silica aggregates should be broadcasted onto the slurry. KingCoat CT100 cures to a durable, anti-slip, extremely hard wearing surface. Depending on the used Antislip Aggregate, final dry thickness can be (3 - 3.5 mm) for medium traffic or (5 - 5.5 mm) for heavy traffic.
Where to use
KingCoat CT100 is used to provide a hard wearing anti-skid surface for concrete and steel floors for a wide range of applications such as:
- Car parks.
- Roads and bridges.
- Offshore oil platforms.
- Ship decks.
- Industrial floors.
- Helicopter decks (pad).
Why use it
- Hard wearing system.
- Non-slip.
- Solvent free.
- Lightweight.
- Fast cure.
- Waterproof.
- Flexible.
- Resists a wide range of chemicals, consult KINGKRETE technical department for more details.
Technical properties
| Specific gravity | 1.75 ± 0.05 |
|---|---|
| Working life | 60 - 80 min @ 15°C 40 - 50 min @ 25°C 20 - 30 min @ 35°C |
| Foot traffic | After 24 hr @ 25°C |
| Vehicular traffic | After 48 hr @ 25°C |
| Full cure | 7 days @ 25°C 4 days @ 35°C |
| Compressive strengthBS 6319-2 | ≥ 45 MPa @ 7 days |
| Flexural strengthEN 13892-2 | ≥ 25 MPa @ 7 days |
| Tensile strengthBS 6319-7 | ≥ 8 MPa @ 7 days |
| Maximum wear depthBS EN 13892-4 | 0.01 mm |
| Bond strengthBS EN 13892-8 | > 2 MPa (concrete failure) |
| Impact resistanceISO 6272-2 | Pass to 10 N.m (on concrete substrate) |
| Water permeability (5 bar)DIN 1048 | Nil |
| Water absorptionASTM D570 | Nil |
| VOCASTM D2369 | < 10g/ltr |
Standards and approvals
KingCoat CT100 complies with EN 13813, SR-B2.0-AR0.5- IR10.
How to use
Substrate preparation
The substrate must be clean, dry, even, dense and free from oil, grease, dust and other contaminants. A clean surface will ensure maximum adhesion between the substrate and the coating.
Concrete floors must have a minimum compressive strength of 25 N/mm² and a maximum concrete relative humidity of 80% (max. moisture content of 4%), relative humidity can be measured with hygrometers.
Concrete relative humidity should be less than 80% for concrete of 28 days old or more, for low W/C ratio concrete floors, 80% hygrometer reading or less can be achieved before 28 days age.
When applied to steel substrates, all surfaces should be clean and free from rust and scale. Make sure that the surfaces are grit blasted to reach a bright finish meets the requirement of Swedish Standard to a minimum of SA 2 ½ grade.
Contact KINGKRETE Technical Department for further details.
Surface preparation
Unsound layers and contaminated concrete surfaces must be prepared using mechanical surface removing equipment. For deeply contaminattion by oil or grease, such areas should be treated with hot compressed air.
Priming
Concrete and steel substrates should be primed with KingFloor Primer/Primer S. Use lamb's wool roller to apply the primer. The primer should be allowed to cure for 24 hours. More than one coat may be required for highly porous or textured surfaces.
For more information about the best priming procedure, contact KINGKRETE's Technical Department.
Mixing
To avoid inconsistent workability and pot life, make sure the materials to be used are stored in a shaded area and protected from extremes of temperatures for at least 24 hours prior to application. Prior to mixing, stir the liquid components of KingCoat CT100 (base & hardener), mix thoroughly for at least 3 minutes using a forced action mixer. Add the filler and mix until a homogenous mixture is formed, this will take about 4 - 5 minutes.
| Chemical Resistance (ASTM D543) | |
|---|---|
| Acids (m/v) | |
| Hydrochloric Acid 10% | Resistant |
| Nitric Acid 10% | Resistant |
| Phosphoric Acid 10% | Resistant |
| Sulphuric Acid 10% | Resistant |
| Alkalis (m/v) | |
| Ammonia 15% | Resistant |
| Sodium Hydroxide 25% | Resistant* |
| Solvents and organics | |
| Oils, vegetables & minerals | Resistant |
| Ferric Chloride 15% | Resistant |
| Kerosene | Resistant |
| White spirit | Resistant |
| Xylene | Resistant |
| Acetone | Resistant |
| Aqueous solutions | |
| Water | Resistant |
| Sea water | Resistant |
| Raw sewage | Resistant |
| Sodium chloride sat. | Resistant |
| Chlorinated water | Resistant |
| Fuels | |
| Brake fluid | Resistant |
| Diesel | Resistant |
| Kerosene | Resistant |
| UV resistance | Resistant* |
Note: Slight discoloration in some cases may occur without affecting the performance of the coat.
SLURRY LAYING
Work in lanes of width not exceeding 3 m. Spread the slurry on the prepared surface at the required thickness by rack. Care should be taken when joining the lanes, to achieve a smooth connection. It is recommended to mask off edges with tape which is then removed while KingCoat CT100 is still wet.
Dressing the silica aggregate should be applied immediately after laying of KingCoat CT100 slurry. Aggregate should be allowed to fall vertically until the surface is saturated and totally covered.
Remove excess aggregate after initial curing of KingCoat CT100. Excess aggregates can be reused if not contaminated during removal.
POINTS TO BE CONSIDERED
- KingCoat CT100 should not be applied on to surfaces known to suffer from damp rising.
- Ramps should be treated with larger size silica aggregates.
- KingCoat CT100 should not be applied at temperatures below 10°C or where ambient relative humidity exceeds 80%.
Cleaning
KingCoat CT100 can be removed with KINGKRETE solvent prior to setting.
Coverage, packaging and storage
Coverage
KingCoat CT100: 6.1 kg/m² @ 3.5 mm thickness, and 9.6kg/ m² @ 5.5 mm thickness.
KingFloor Primer: 5 m²/kg @ 200 microns DFT.
Silica aggregates: 5 - 6 kg/m² using Antislip Aggregate #2, and 6.5 - 7.5 kg/m2 using Antislip Aggregate #0.
Packaging
KingCoat CT100 is available in 30 kg packs. KingFloor Primer is available in 5 kg packs.
Silica aggregates is available in 25 kg bags.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.