Compressive strength BS 6319-2
≥ 44 MPa @ 7 days
Flexural strength BS 6319-3
≥ 18 MPa @ 7 days
Tensile strength BS 6319-7
≥ 6 MPa @ 7 days
Specific gravity
2 ± 0.1

Overview

KingCoat CT500 is a heavy duty solvent free coal tar modified epoxy flooring screed system. Components of product composed of a base, hardener, filler and graded aggregate which when mixed form a homogenous screed. KingCoat CT500 cures to a durable, anti-slip, extremely hard wearing surface.

Where to use

KingCoat CT500 is used to provide a hard wearing anti-skid surface for concrete and steel floors for a wide range of applications such as:

  • Car parks.
  • Roads and bridges.
  • Offshore oil platforms.
  • Ship decks.
  • Industrial floors.
  • Helicopter decks (pad).

Why use it

  • Hard wearing system.
  • Non-slip.
  • Solvent free.
  • Fast cure.
  • Waterproof.
  • Flexible.
  • Resists a wide range of chemicals, consult KINGKRETE technical department for more details.

Technical properties

Specific gravity2 ± 0.1
Working life60 - 80 min @ 15°C
40 - 50 min @ 25°C
20 - 30 min @ 35°C
Foot trafficAfter 24 hr @ 25°C
Vehicular trafficAfter 48 hr @ 25°C
Full cure7 days @ 25°C
4 days @ 35°C
Recommended
application thickness
3 - 9 mm
Compressive strengthBS 6319-2≥ 44 MPa @ 7 days
Flexural strengthBS 6319-3≥ 18 MPa @ 7 days
Tensile strengthBS 6319-7≥ 6 MPa @ 7 days
Maximum wear
depthBS EN 13892-4
0.09 mm
Bond strengthBS EN 13892-8> 2 MPa
(concrete failure)
Impact resistanceISO 6272-2> 10 N.m
Water permeability
(5 bar)DIN 1048
Nil
Water absorptionASTM D570≤ 0.01%
VOCASTM D2369< 10g/ltr

For asphalt substrates, it should be clean, dry and better to be 8 months old. As no primer for asphalt substrates is required, it is important to have a well prepared substrate; mechanical surface removing equipments as grit blasting can be used.

Contact KINGKRETE Technical Department for further details.

Standards and approvals

KingCoat CT500 complies with EN 13813, SR-B2.0- AR0.5-IR10.

How to use

Substrate preparation

The substrate must be clean, dry, even, dense and free from oil, grease, dust and other contaminants. A clean surface will ensure maximum adhesion between the substrate and the coating. Concrete floors must have a minimum compressive strength of 25 N/mm².

Concrete relative humidity should be less than 80% for concrete of 28 days old or more, for low W/C ratio concrete floors, 80% hygrometer reading or less can be achieved before 28 days age. Steel substrates should be blast cleaned to a minimum of Sa2½.

Surface preparation

Unsound layers and contaminated concrete surfaces must be prepared using mechanical surface removing equipment. In case of areas deeply contaminated by oil or grease, such areas should be treated with hot compressed air.

Priming

Concrete substrates should be primed with KingFloor Primer. Use lambs wool roller to apply the primer. Apply KingCoat CT500 whilst the primer still wet.

Mixing

To avoid inconsistent workability and pot life, make sure that the materials to be used are stored in shaded area and protected from extremes of temperatures for at least 24 hours prior to application. Prior mixing, stir the liquid components of KingCoat CT500 (base & hardener), mix thoroughly for at least 3 minutes using a forced action mixer. Add the filler and the aggregate and mix until a homogenous mixture is formed, this will take about 4 -5 minutes.

LAYING

Work in lanes of width not exceeding 3 m. Spread the screed on the prepared surface at the required thickness by rack, then tamping and compaction is done by means of proper wooden float and screeding bar or steel trowel. Care should be taken when joining the lanes, to achieve a smooth connection. It is recommended to mask off edges with tape which is then removed while KingCoat CT500 is still wet.

POINTS TO BE CONSIDERED

  • KingCoat CT500 should not be applied on to surfaces known to suffer from damp rising.
  • KingCoat CT500 should not be applied at temperatures below 10°C or where ambient relative humidity exceeds 80%.
Cleaning

KingCoat CT500 can be removed by KINGKRETE solvent prior setting.

Coverage, packaging and storage

Coverage

KingCoat CT500: 3m²/pack/5 mm thickness. KingFloor Primer: 4 - 5 m²/liter.

Chemical Resistance (ASTM D543)
Acids (m/v)
Hydrochloric Acid 10%Resistant
Nitric Acid 10%Resistant
Phosphoric Acid 10%Resistant
Sulphuric Acid 10%Resistant
Alkalis (m/v)
Ammonia 15%Resistant
Sodium Hydroxide 25%Resistant*
Solvents and organics
Oils, vegetables &
minerals
Resistant
Ferric Chloride 15%Resistant
KeroseneResistant
White spiritResistant
XyleneResistant
AcetoneResistant
Aqueous solutions
WaterResistant
Sea waterResistant
Raw sewageResistant
Sodium chloride sat.Resistant
Chlorinated waterResistant
Fuels
Brake fluidResistant
DieselResistant
KeroseneResistant
UV resistanceResistant

Note: Slight discoloration in some cases may occur without affecting the performance of the coat.

Packaging

KingCoat CT500 is available in 30 kg packs (15 ltr), consisting of:

  • 4.35 kg Binder (part A & B).
  • 10.15 kg Filler.
  • 15.5 Aggregate.

KingFloor Primer is available in 5 kg packs.

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.