🌍 🌐 English
Flooring

KingFloor EP100®

Solvent free high build epoxy floor coating for thickness up to 200 microns in one coat

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Compressive strength BS 6319-2
≥ 80 MPa @ 7 days
Flexural strength EN 13892-2
≥ 30 MPa @ 7 days
Tensile strength ASTM D638
≥ 20 MPa @ 7 days
Mixed density
1.40 ± 0.05 g/cm³

Overview

KingFloor EP100 is a high build, hard wearing, solvent free epoxy resin coating, designed to provide a hard, gloss coating to concrete floors. It is supplied as two pack material in addition to a colour pack in pre weighted quantities ready for onsite mixing and use.

KingFloor EP100 permits the application of floor coatings in excess of 200 microns per coat and can be coloured to suit site requirements.

With the addition of Antislip Aggregate (Slip resistant aggregate No. 2 or 3) between coats, slip resistant floor system can be achieved with a buildup thickness between

1.25 to 2 mm.

Where to use

KingFloor EP100 is used as protective, decorative, high chemical resistance and hard wearing floor coating system for a wide range of applications including:

  • Aircraft hangars.
  • Car parks.
  • Soft drink and beverage production areas.
  • Dairies production areas.
  • Show rooms.
  • Hospitals.
  • Production, maintenance and assembly areas.
  • Warehouses.
  • General food processing and manufacturing plants.

Why use it

  • Produces a seamless, glossy, glass-like surface that is both easy to clean and does not induce bacterial and fungal growth.
  • High chemical and mechanical resistance.
  • Available in a wide range of attractive colours.
  • Cost effective.
  • Easy application.
  • High build.

Technical properties

Values @ 25º

ColourAvailable in different colours
Mixed density1.40 ± 0.05 g/cm³
Solid contents100%
Pot life50 - 70 min @ 25°C
20 - 40 min @ 35°C
Minimum time between
coats
12 hr @ 25°C
6 hr @ 35°C
Maximum time between
coats
36 hr @ 25°C
18 hr @ 35°C
Full curing time7 days @ 25°C
5 days @ 35°C
Compressive strengthBS 6319-2≥ 80 MPa @ 7 days
Flexural strengthEN 13892-2≥ 30 MPa @ 7 days
Tensile strengthASTM D638≥ 20 MPa @ 7 days
Bond strength on
C25/30 concreteASTM D4541EN 1542
≥ 2 MPa @ 7 days
(concrete failure)
Shore D hardness @
14 daysASTM D2240
85
Water absorptionASTM D570≤ 0.15%
Taber abrasion
resistance
(1000 g, 1000 cycle)ASTM D4060, weight
loss
CS17 wheel
≤ 65 milligram
VOCASTM D2369≤ 10 g/ltr
(complies with LEED)

Standards and approvals

KingFloor EP100 complies with the requirements of EN 1504-2, Surface Protection Systems principle 5.1.

How to use

Substrate preparation

The substrate must be clean, dry, even, dense and free from oil, grease, dust and other contaminants.

A clean surface will ensure maximum adhesion between the substrate and the coating. Concrete floors must have a minimum compressive strength of 25 N/mm² and a maximum concrete relative humidity of 80% (max. moisture content of 4%), relative humidity can be measured using a hygrometer.

Concrete relative humidity should be less than 80% for concrete 28 days old or more.

Surface preparation

Unsound layers and contaminated concrete surfaces must be prepared using mechanical surface removing equipment. Acid etching can be used only in well ventilated areas. Areas deeply contaminated by oil or grease, such areas should be treated by hot compressed air.

Priming

KingFloor EP100 is designed to be used without a primer. However, for highly porous substrates, KingFloor Primer or KingFloor Primer S is recommended.

Mixing

To avoid inconsistent workability and pot life, make sure that the materials to be used are stored in shaded area and protected from extremes of temperatures, for at least 24 hours prior to application.

Prior to mixing, stir individual components of Resin, Hardener and colour pack. Add the entire content of the colour pack into the base container and mix with heavy duty drill for 2 minutes till a uniform colour is achieved. Add the entire contents of the hardener container to the mixed colour pack and base and mix thoroughly for at least 3 minutes.

Occassional Spillage.
Chemical Resistance after full cure (7 days @ 25°C), ASTM D1308 (spot test @ 1 hr)
Organic acids
Oleic Acid sat.R
Citric Acid 25%R
Acetic Acid 5%R
Acetic Acid 10%SS
YogurtR
Lactic Acid 10%RS + SS
Inorganic Bases
Sodium Hydroxide 50%R
Ammonia Solution 10%R
Potassium Hydroxide 50%R
Aqueous Solutions
Sodium Chloride satR
Tap waterR
Chlorinated waterR
Dead sea waterR
Solvents
White spiritR
XyleneR
TolueneR
AcetoneR
Oils & Fuels
Brake fluidR
Engine oilR
DieselR
KeroseneR
Detergents & SoapsR
Inorganic Acids
Sulphuric Acid 25%R
Sulphuric Acid 40%R
Phosphoric Acid 20%RS
Hydrochloric Acid 10%R
Hydrochloric Acid 32%RS
Nitric Acid 10%R

R: Resistant
RS: Resistant with slight discoloration
SS: Slight softining

COATING

Use brush or lambs wool roller, or airless spray machine to apply the mixed KingFloor EP100 onto the prepared surfaces.

To get a film thickness of 400 microns, apply 2 coats of KingFloor EP100 at 3.5 m²/kg per coat, second coat should be applied at a right angle to the first coat. The second coat may be applied as soon as the first coat has initially dried.

When KingFloor Primer is used at a rate of 5 m2/kg, it will give a dry film thickness between 120 - 150 microns with a clear yellow glossy finish.

Antislip Application

The base coat should be applied at a minimum film thickness of 200 - 250 microns depending on Anti-slip Aggregate used and then fully blinded with the chosen Anti-slip Aggregate. Once the base coat has reached initial cure, all excess aggregates should be removed before a further application of KingFloor EP100 top coat.

The top coat should be applied at a minimum film thickness of 290 - 320 microns depending on Anti-slip Aggregate size used.

REMARKS

  • KingFloor EP100 should not be applied at temperatures below 10°C or where ambient relative humidity exceeds 85%.
  • KingFloor EP100 should not be applied onto surfaces known to suffer from rising damp.
  • In case of spray applications, airless spray machines should be used.
  • A minimum thickness of 150 microns per coat should be applied to obtain a smooth finish.
Cleaning

Tools and equipment can be cleaned with KINGKRETE Solvent when it is wet. Dried KingFloor EP100 may be removed mechanically.

Coverage, packaging and storage

Coverage

Standard coverage

KingFloor Primer S: 5 m²/kg.

KingFloor EP100(base coat): 0.28 - 0.29 kg/m². KingFloor EP100 (top coat): 0.28 - 0.29 kg/m². Approximate system thickness: 500 - 600 microns.

Antislip coverage when used with Anti-slip Aggregate #2 to achieve medium texture:

KingFloor Primer S: 5 m²/kg.

KingFloor EP100 (base coat): 0.35 kg/m².

Antislip aggregate #2: 2.0 – 4.0 kg/m².

KingFloor EP100 (top coat): 0.45 kg/m².

Approximate system thickness: 2.0 mm.

Antislip coverage when used with Anti-slip Aggregate #3 to achieve fine texture:

KingFloor Primer S: 5 m²/kg.

KingFloor EP100 (base coat): 0.30 kg/m².

Antislip aggregate #3: 2.0 – 4.0 kg/m².

KingFloor EP100 (top coat): 0.40 kg/m².

Approximate system thickness: 1.25 mm.

Packaging

KingFloor EP100 is available in 6 kg packs (4.25 litre), 18 kg packs (12.75 litre) and 30 kg packs (21.3 litre).

CHEMICAL RESISTANCE
Based on test method ASTM D1308, immersion in the below chemicals. After 7 days
Hydrochloric Acid 32%RS
Sulphuric Acid 25%R
Sodium Hydroxide 50%R
PetrolR
KeroseneR
SkydrolR
Engine oilR
Brake fluidR
Saturated Sugar SolutionR

R: Resistant
RS: Resistant with slight discoloration

Performance characteristicsEN 1504-2
requirement
Measured value
Abrasion resistance: (1000 g, 1000 cycles)EN ISO 5471-1
H22 wheel
≤ 3000 mg≤ 1500 mg
Impact resistance: EN ISO 6272-1≥ 10 N.m≥ 10 N.m
(Class II)
Capillary water absorptionEN 1062-3< 0.1 kg/m².h⁰·⁵≤ 0.005 kg/ m².h⁰·⁵
Adhesion strength: EN 1542≥ 1 MPa without trafficking
≥ 2 MPa with trafficking
≥ 3.0 MPa
(Rigid system with trafficking)

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet