🌍 🌐 English
Flooring

KingFloor UN200®

Epoxy roller coatings and self-levelling floor toppings.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Shore D hardness ASTM D2240
≥ 80
Mixed density: (neat resin)
1.45 ± 0.1 g/cm³
Solids content
100%

Overview

KingFloor UN200 is a two component multi-use epoxy resin. It can be used either as a smooth roller coating, textured roller coating, self-levelling floor topping or as a broadcast system.

Where to use

  • Floor coatings with different surface finishes.
  • Self-levelling floor toppings with either smooth or broadcast surface finishes.
  • KingFloor UN200 can be used to over-coat KingFloor UN100 flooring systems as a decorative and protective final layer of the flooring system.

Why use it

  • Excellent adhesion.
  • Aesthetic look.
  • Can be used for multiple applications.

SYSTEM COMPONENTS

  • For use as a smooth roller coating

Primer coat: 1 - 2 coats of KingFloor UN100 (optional)*

Coating: 1 - 2 coats of KingFloor UN200

  • For use as a textured roller coating

Primer coat: 1 - 2 coats of KingFloor UN100 (optional)*

Coating: 1 coat of KingFloor UN200 + Kingkrete Extender

C) For use as a coarser roller coating with improved slip resistance

Primer coat: 1 - 2 coats of KingFloor UN100

Coating: 1 coat of KingFloor UN200 + KingFloor UN200 Filler #3 (0.1 - 0.8 mm) + Kingkrete Extender

D) For use as a low thickness self-levelling floor topping

Primer coat: 1 - 2 coats of KingFloor UN100

Floor topping: 1 coat of KingFloor UN200 + KingFloor UN200 Filler #5 (top cut 0.1 mm)

Technical properties

Values @ 25°C

Mixed density: (neat resin)1.45 ± 0.1 g/cm³
Solids content100%
Compressive strengthBS 6319-2Resin (filled 1:1)
> 48 MPa @ 7 days
Flexural strengthBS 6319, Part 3Resin (filled 1:1)
> 35 MPa @ 7 days
Tensile strengthBS 6319, Part 7Resin (filled 1:1)
> 13 MPa @ 7 days
Abrasion resistance
(1000 g, 1000 cycle)ASTM D4060, weight
loss
CS17 wheel
Resin (filled 1:0.4)
< 145 milligram
Shore D hardnessASTM D2240≥ 80
Foot trafficAfter 24 hr
VOCASTM D2369< 50 g/ltr

E) For use as a medium thickness self-levelling floor topping

Primer coat: 1 - 2 coats of KingFloor UN100

Floor topping: 1 coat of KingFloor UN200 + KingFloor UN200 Filler #4 (0.1 - 0.3 mm)

F) For use as a broadcast system

Primer coat: 1 - 2 coats of KingFloor UN100

Floor topping: 1 coat of KingFloor UN200 + KingFloor UN200 Filler #4 (0.1 - 0.3 mm)

Aggregate dressing: Antislip Aggregate #2 or #3 Sealcoat: 1 coat of KingFloor UN200

* Priming low to medium absorbent substrates is not necessarily required.

How to use

Substrate preparation

Concrete substrates should be fully cured and achieve a minimum compressive strength of 25 N/mm2 and a minimum pull-off strength of 1.5 N/mm2.

The concrete substrate should be below 75% RH and have less than 4% moisture content. Alternatively, KingFloor DPM should be used after consulting with KINGKRETE’s Technical Department.

COVERAGE
ComponentMixed Resin : Sand : Kingkrete
Extender
mixing ratio
KingFloor UN200 Filler
(Quartz Sand
Gradation)
Coverage RateThickness
A) Smooth roller coating1 : 0 : 0
(no sand or extender needed)
-0.30 - 0.35 kg/m²/coat200 – 240
microns/coat
B) Textured roller coating1 : 0 : 0.015
(no sand needed)
-0.50 - 0.80 kg/m²350 - 550 microns
C) Coarser roller coating with improved slip resistance10: 1 : 0.015KingFloor Filler #3
(0.1 - 0.8 mm)
0.6 - 0.9 kg/m²400 - 600 microns
D) Low thickness self- levelling floor topping1 : 0.4 : 0
(no sand needed)
KingFloor Filler #5
(Top cut 0.1 mm)
1.65 kg/m²/mm1 mm
E) Medium thickness self-levelling floor topping1 : 1 : 0
(no extender needed)
KingFloor Filler #4
(0.1 - 0.8 mm)
1.95 kg/m²/mm1.5 - 3 mm
F.1) Broadcast
System
1 : 1 : 0
(no extender needed)
Broadcast Antislip Aggregate
#2 or #3 and seal with
KingFloor UN200 sealcoat
KingFloor Filler #4
(0.1 - 0.3 mm)
1.95 kg/m²/mm and
6 kg/m² for Antislip
Aggregate #2 or #3
Depending on
Antislip
Aggregate used
F.2) Sealcoat1 : 0 : 0
(no sand or extender needed)
0.5 kg/m²340 microns
Surface preparation

Concrete surfaces must be degreased using degreasing products, torching or any other suitable method which assures the surface is free from any oil traces.

Concrete surfaces are to be mechanically prepared to remove laitance and achieve a flat surface, grit blasting or surface profiling equipment are preferred. Acid etching can be used after consulting with KINGKRETE's Technical Department.

Surface defects such as voids and blowholes should be repaired before application. Consult KINGKRETE's Technical Department for the best repair material.

Surfaces must be free of any dust or loose particles before product application. Use suitable methods like vacuuming or sweeping. If possible, apply the product on a small test area before actual application to check for any problems with the surface preparation.

Priming

If a primer is needed according to the system components section, KingFloor UN100 primer shall be applied using a brush, roller or squeegee to obtain a continuous primer coat. If needed, apply an additional coat of KingFloor UN100, and allow to dry before the primer is covered with other flooring systems. For further details, please refer to KingFloor UN100 technical data sheet.

Mixing

Prior to mixing, stir individual components of KingFloor UN200. Add the KingFloor UN200 hardener to the base and using a jiffy-type mixer attached to a slow running electric drill, mix for approximately 2 minutes.

Once the KingFloor UN200 hardener and base have been mixed, transfer the entire contents into a Casco or Creteangle-type mixer, taking care to ensure that the bottom and sides are thoroughly scraped.

Start the mixer and transfer to it the entire contents of the KingFloor UN200 quartz sand and a suitable extender (fine filler) if necessary, taking care to ensure that these are completely dry and lump-free. Continue mixing for approximately 2 minutes.

Note: Never mix KingFloor UN200 by hand as this could lead to areas of uncured material.

Application

A, B & C) Coatings

Apply KingFloor UN200 as coating using a roller or brush to the required thicknesses.

D & E) Self-leveling floor toppings

Pour the mixed material onto the primed surface and spread using a trowel or rake at the required thickness and allow to attain a smooth finish. While still wet, thoroughly spike roll KingFloor UN200 in two directions to help eliminate the entrapped air.

F) Broadcast system

Pour the mixed material of the medium thickness self- levelling floor topping onto the primed surface and spread using a trowel or rake at the required thickness and allow to attain a smooth finish.

While still wet, thoroughly spike roll KingFloor UN200 to help eliminate the entrapped air. While still wet, broadcast with Antislip Aggregate #2 or #3 to excess and wait until it gets dry, then remove excess aggregate. Apply KingFloor UN200 sealcoat with a roller at the required thickness.

Cleaning

KingFloor UN200 can be removed by KINGKRETE solvent prior setting.

Chemical Resistance spot test @ 1 hour (after full cure 7 days) ASTM D1308
Sulphuric Acid 25%Resistant
Phosphoric Acid 20%Discoloration
Hydrochloric Acid 10%Resistant
NaOH 50%Resistant
Brake FluidResistant
NaCl saturatedResistant
Citric Acid 25%Slightly discoloration
Lactic Acid 10%Discoloration
XyleneResistant

Coverage, packaging and storage

Packaging

Option 1

Base: 25 kg.

Hardener: 5 kg.

Base and hardener: 30 kg.

Option 2

Base: 220 kg drum.

Hardener: 44 kg drum.

Base and hardener: 1 drum (220 kg) base and 1 drum (44 kg) hardener = 264 kg.

Option 3

Base: 220 kg drum. Hardener: 132 kg drum.

Base and hardener: 3 drums (220 kg) base and 1 drum (132 kg) hardener = 792 kg.

Contact KINGKRETE for the proper KingFloor UN200 Filler packaging details based on the flooring system required.

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet