Mixed density: (neat resin)
1.5 ± 0.1 g/cm³
Solid content
100%

Overview

KingFloor UN100 is a two component multi-use epoxy resin. It can be used as a primer, in addition, it can be mixed with different filler gradations to be used as a levelling mortar, self-levelling intermediate layer, repair mortar or floor screed.

Where to use

  • Primer: over concrete and cementitious floors and epoxy mortars.
  • Repair mortar: as a patching or a levelling mortar.
  • Flooring underlayment: as a self-levelling intermediate layer or a floor screed.
  • KingFloor UN100 can be over-coated with KingFloor UN100 UN201 decorative and protective epoxy flooring systems.

Why use it

  • Good penetration.
  • Excellent adhesion.
  • Can be used for multiple applications.
  • Highly durable.
  • KingFloor UN100 screed system can be used in
  • freezer rooms for temperatures down to -25°C.

SYSTEM COMPONENTS

A) For use as a primer

Primer coat: 1 - 2 coats of KingFloor UN100

B) For use as a low thickness levelling mortar (surface roughness < 1 mm)

Primer coat:1 - 2 coats of KingFloor UN100

Levelling mortar: 1 coat of KingFloor UN100 + quartz sand (0.1 - 0.3 mm) + a suitable extender (fine filler)

C) For use as a medium thickness levelling mortar (surface roughness up to 2 mm)

Primer coat: 1 - 2 coats of KingFloor UN100

Levelling mortar: 1 coat of KingFloor UN100 + quartz sand (0.1 - 0.3 mm) + a suitable extender (fine filler)

D) For use as a self-levelling intermediate layer (1.5 to 3 mm)

Primer coat:1 - 2 coats of KingFloor UN100

Levelling mortar: 1 coat of KingFloor UN100 + quartz sand (0.1 - 0.3 mm)

Optional: Antislip Aggregate #2 or #3, and seal

with KingFloor UN200UN201 smooth roller coating.

Technical properties

Values @ 25°C

Mixed density: (neat resin)1.5 ± 0.1 g/cm³
Solid content100%
Foot trafficAfter 24 hr
Full cure7 days
Compressive strength: BS
6319-2
≥ 55 MPa @ 7 days
Screed (filled 1:8)
Flexural strength: EN
13892-2
≥ 20 MPa @ 7 days
Screed (filled 1:8)
Tensile strengthBS 6319-7≥ 10 MPa @ 7 days
Screed (filled 1:8)
Bond strength on C25/30
concrete: EN 1542
≥ 2.5 MPa
(substrate failure)
Shore D hardness: ASTM
D2240
≥ 80
Impact resistanceISO 6272-2Pass @ 10 N.m
(no cracks or peel)
VOCASTM D2369< 50 g/ltr

E) For use as a floor screed (15 - 20 mm thickness) or repair mortar

Primer coat: 1 - 2 coats of KingFloor UN100

Bondingkey: 1 coat of KingFloor UN100

Screed: 1 coat of KingFloor UN100 + suitable sand mixture (to be applied when the bonding key layer is still tacky)

How to use

Substrate preparation

Concrete substrates should be fully cured and achieve a minimum compressive strength of 25 N/mm² and a minimum pull-off strength of 1.5 N/mm².

The concrete substrate should be below 75% RH and have less than 4% moisture content. Alternatively, KingFloor DPM should be used after consulting with KINGKRETE’s Technical Department.

COVERAGE
ComponentMixed resin : Sand : A suitable extender (fine filler)
mixing ratio
Quartz Sand
Gradation
Coverage RateThickness
A) Primer1 : 0 : 0
(no sand or extender needed)
-0.38 - 0.60 kg/m²/coat250 – 400
microns/coat
B) Low thickness
levelling mortar
(surface
roughness < 1
mm)
1 : 0.5 : 0.0050.1 - 0.3 mm1.8 kg/m²/mmDepending on
substrate surface
roughness
C) Medium
thickness leveling
mortar (surface
roughness up to 2
mm)
1 : 1 : 0.0050.1 - 0.3 mm1.95 kg/m²/mmDepending on
substrate surface
roughness
D) Self levelling
intermediate layer
1 : 1 : 0 (no extender needed)
Optional: for an anti-slip finish,
broadcast Antislip Aggregate #2 or
#3 and seal with KingFloor UN200UN201
smooth roller coating
0.1 - 0.3 mm1.95 kg/m²/mm and
4 kg/m² for Antislip
Aggregate #2 or #3
Smooth finish:
2 mm
Anti-slip finish:
depending on
Antislip Aggregate
used
E.1) Bonding key1 : 0 : 0
(no sand or extender needed)
-0.40 - 0.64 kg/m²265 - 425 microns
E.2) Screed/repair
mortar
1 : 8 : 0
(no extender needed)
Suitable sand
gradation*
(as note
below)
2.0 kg/m²/mm15 - 20 mm

* Note: the following is a recommended quartz sand gradation for layer thickness of 15 - 20 mm: 20 parts by weight (pbw) quartz sand 0.1 - 0.3 mm
30 parts by weight (pbw) quartz sand 0.1 - 0.7 mm 50 parts by weight (pbw) quartz sand 0.5 - 1.0 mm
Note : the maximum grain size shall not exceed 1/3 of the floor screed thickness, grain shape should be taken into consideration when selecting the best suitable quartz sand gradation.

Surface preparation

Concrete surfaces must be degreased using degreasing products, torching or any other suitable method which assures the surface is free from any oil traces.

Concrete surfaces are to be mechanically prepared to remove laitance and achieve a flat surface, grit blasting or surface profiling equipment are preferred. Acid etching can be used after consulting with KINGKRETE's Technical Department.

Surface defects such as voids and blowholes should be repaired before application. Consult KINGKRETE's Technical Department for the best repair material.

Surfaces must be free of any dust or loose particles before product application. Use suitable methods like vacuuming or sweeping

If possible, apply the product on a small test area before actual application to check for any problems with the surface preparation.

Mixing

Base: Hardener mixing ratio = 86 : 14 (by weight)

Prior to mixing, stir individual components of KingFloor UN100. Add the KingFloor UN100 hardener to the base and using a jiffy-type mixer attached to a slow running electric drill, mix for approximately 2 minutes. Once the KingFloor UN100 hardener and base have been mixed, transfer the entire contents into a Casco or Creteangle-type mixer, taking care to ensure that the bottom and sides are thoroughly scraped. Start the mixer and transfer to it the entire contents of the KingFloor UN100 quartz sand and a suitable extender (fine filler) if necessary, taking care to ensure that these are completely dry and lump-free. Continue mixing for approximately 2 minutes.

Note: Never mix KingFloor UN100 by hand as this could lead to areas of uncured material.

Application
  • Primer

KingFloor UN100 can be applied using a brush, roller or squeegee to obtain a continuous primer coat. If needed, apply an additional coat of KingFloor UN100, and allow to dry before the primer is covered with other flooring systems.

B & C) Leveling mortar

Apply KingFloor UN100 onto the primed surface as a levelling mortar using a squeegee or a trowel to the required thicknesses.

D) Self-leveling intermediate layer

Pour the mixed material onto the primed surface and spread using a trowel or rake at the required thickness and allow to attain a smooth finish.

While still wet, thoroughly spike roll KingFloor UN100 to help eliminate the entrapped air. If an anti-slip finish is required, while the self-levelling mortar is still wet, broadcast with Anti-slip Aggregate #2 or #3 to excess and wait until it gets dry, then remove excess aggregate.

Seal the system with KingFloor UN200 smooth roller coating. The coating can be applied using a roller or brush at the required thickness.

E) Floor screed/ repair mortar

Apply KingFloor UN100 bonding key onto the primed surface using a brush, roller or squeegee.

While the bonding key is still tacky, apply KingFloor UN100 evenly using a trowel at the required thicknesses. The material should be tamped well in place and finished with a steel trowel to achieve the required smoothness.

Cleaning

KingFloor UN100 can be removed by KINGKRETE solvent prior setting.

Coverage, packaging and storage

Packaging

Option 1

Base: 25.7 kg.

Hardener: 4.3 kg.

Base and hardener: 30 kg.

Option 2

Base: 220 kg drum.

Hardener: 37 kg drum.

Base and hardener: 1 drum (220 kg) base and 1 drum (37 kg) hardener = 275 kg.

Option 3

Base: 220 kg drum.

Hardener: 110 kg drum.

Base and hardener: 3 drums (220 kg) base and 1 drum (110 kg) hardener = 770 kg.

Contact KINGKRETE for the proper quartz sand packaging details based on the flooring system required.

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet