🌍 🌐 English
Flooring

KingFloor PA250®

High solids epoxy polyamide coating.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Pot life
180 - 200 min @ 25°C
Mixed density
1.25 ± 0.05 g/cm³
Solid content
70 ± 2%

Overview

KingFloor PA250 is a high solids epoxy polyamide coating for use over well prepared steel, concrete and previously coated surfaces. The product has excellent adhesion properties and good flexibility and resistance to abrasion and chemicals.

Where to use

KingFloor PA250 is designed for use directly on metal substrates in high performance architectural applications and on primed substrates for many applications in industrial environments such as:

Institutional, industrial, commercial, and laboratories walls.

Metal structures.

Chemical processing equipment.

Food and chemical industries, laundries and power plants.

Exterior protection of pipes and tanks.

Why use it

High chemical and mechanical resistance.

Excellent adhesion to concrete and steel surfaces.

High abrasion, wear and impact resistance.

Good flexibility, suitable for low temperature exposure conditions.

Cost effective.

Easy application.

Technical properties

ColourWide range of colours
FinishGloss
Mixed density1.25 ± 0.05 g/cm³
Solid content70 ± 2%
Volume solids56 ± 2%
Pot life180 - 200 min @ 25°C
Tack free time3 - 4 hr @ 25°C
Dry time, dry hardASTM D16401 - 2 hr @ 25°C
Dry film thickness65 - 100 microns per coat
Minimum over coating
time
4 hr @ 25°C
Maximum over coating
time
7 days @ 25°C
Minimum application
temperature
10°C
Full cure7 days @ 25°C
Bond strengthASTM D4541≥ 7 MPa (concrete failure)
≥ 7 MPa (on steel)
Impact resistanceASTM D279410 N.m
FlexibilityASTM D522, 180° bend,
1/4" mandrel
Passes
Pencil Hardness
F-H according to ASTM
D3363
Passes
Taber abrasion
resistance
(1000 g, 1000 cycle)ASTM D4060, weight
Loss CS17 wheel
80 mg @ 14 days
Dry heat resistance93°C (No loss of adhesion
was observed @ 180°
bend, 5/8" (16 mm)
mandrel
VOCASTM D2369< 450 g/ltr

Concrete

Highly porous concrete surfaces should be primed with KingFloor Primer S.

How to use

Method of use

Substrate Preparation

Steel Surfaces

All surfaces should be grit blasted to reach a bright finish meeting the requirement of Swedish Standard SA 2 1/2. Do not leave blasted steel uncoated overnight.

Concrete surfaces

The Substrate should be sound, clean and free from contamination. Surface Laitance should be removed by grit blasting or water jetting. All blow holes should be filled with epoxy paste such as KingRep EP10.

Priming

Steel

KingFloor PA250 is designed to be used without a primer. However, on steel surfaces, use KingFloor PA250 Primer when rust inhibitive primer is specified as the first coat.

Mixing

To avoid inconsistent workability and pot life, make sure that the materials to be used are stored in shaded area and protected from extremes of temperatures, for at least 24 hours prior to application.

Prior to mixing, stir individual components of Resin, Hardener and colour pack. Add the entire contents of the colour pack into the base container and mix with for 2 minutes till a uniform colour is achieved.

Add the entire contents of the hardener container to the mixed colour pack and base and mix thoroughly for at least 3 minutes.

COATING

Use brush or lambs wool roller, or airless spray machine to apply the mixed KingFloor PA250 onto the prepared surfaces.

Apply 2 coats of KingFloor PA250 at 4.5 m²/kg/coat to achieve 100 microns dry film thickness, second coat should be applied at a right angle to the first coat.

The second coat may be applied as soon as the first coat has initially dried. Drying time will depend on the substrate and the ambient conditions.

If the over coating time is exceeded the first coat must be abraded with sand paper prior to the application of the second coat.

Adequate ventilation must be provided to ensure that necessary drying and curing of the material is achieved.

Cleaning

All tools should be cleaned immediately after application using KINGKRETE Solvent. Hardened materials must be cleaned mechanically.

Limitations and notes

  • KingFloor PA250 should not be applied at temperatures below 10°C or where ambient relative humidity exceeds 85%.
  • KingFloor PA250 should not be applied onto surfaces known to suffer from rising damp.
  • In case of spray applications, airless spray machines should be used.

Coverage, packaging and storage

Coverage

4.5 m²/kg per coat to achieve 100 microns dry film thickness.

Two coats should be applied to achieve 150 to 200 microns dry film thickness.

Packaging

KingFloor PA250 is available in 5 kg packs (4 litre) and 20 kg packs (16 litre).

Occassional Spillage.
Chemical Resistance after full cure (7 days @ 25°C), ASTM D1308 (Spot - test @ 1 hr)
Organic acids
Acetic Acid 10%RS + SS
Lactic Acid 10%R
Citric acid
Inorganic Bases
Sodium Hydroxide 50%R
Aqueous Solutions
Sodium Chloride satR
Tap waterR
Solvents
Benzyl alcohol
White spiritR
AcetoneR
Oils & Fuels
Brake fluidR
Inorganic Acids
Sulphuric Acid 25%R
Phosphoric Acid 20%RS
Hydrochloric Acid 10%R
Nitric Acid 10%R

R: Resistant
RS: Resistant with slight discoloration
SS: Slight softening

Hardness after chemical/solvent exposure: ASTM D3363
ChemicalExposureHardness
5% Sulphuric Acid1 hrMinimum 7B
15% Hydrochloric Acid1 hrMinimum 7B
20% Sodium Hydroxide1 hrMinimum 7B
Aliphatic hydrocarbon
solvent
2 hrMinimum 7B
Methyl alcohol1 hrMinimum 7B
Motor oil (10W30)2 hrMinimum 7B
Vegetable oil2 hrMinimum 7B

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature. Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet