Flooring
KingDeck HPU System
UV resistant, hard-wearing polyurethane traffic coating system
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
Build-up
Applied in this order, from the substrate up. Layers drawn with a dashed outline are optional.

| No. | Product | Function | Rate or thickness |
|---|---|---|---|
| Substrate | Concrete car park decks (≥25 N/mm² compressive, ≥1.5 N/mm² pull-off, <75% RH, <4% moisture), exposed/outdoor | ||
| 1 | KingDeck Primer U Solvent-free epoxy primer. Overcoat when tack-free, within 24 h. | Primer | 1 coat 0.20-0.30 kg/m² depending on texture/porosity |
| 2 | KingFloor AS100 Optional Grade No. 3. Omitted for smooth finish; remove excess before wearing course. | Broadcast aggregate (into wet primer) | 1-2 kg/m² |
| 3 | KingDeck Wear Coat TE Overcoat with KingDeck Wear Coat TP after 6-8 h. | Pigmented solvent-free PU wearing course | Ramps 0.40-0.45 + 0.20-0.25 kg/m²; aisles anti-slip 1 coat 0.45-0.55 kg/m²; smooth 1 coat 0.25-0.30 kg/m² |
| 4 | KingDeck Wear Coat TP Final coat for UV-exposed areas. | UV-stable PU top coat | Ramps 0.15-0.25 kg/m²/coat; aisles 1 coat 0.15-0.25 kg/m²; smooth 1 coat 0.15-0.20 kg/m² |
Turn the build-up in 3D
Drag to turn. Click to separate the layers.
Build-up options
- For exposed (outdoor) decks
- Ramps & turning circles: Primer U + AS100 No. 3 + TE + 2 coats TP; 1.25-1.50 mm
- Aisles & bays anti-slip: Primer U + AS100 No. 3 + 1 coat TE + 1 coat TP; 1.15-1.40 mm
- Aisles & bays smooth: Primer U + 1 coat TE + 1 coat TP, no aggregate; 0.45-0.55 mm
- Where waterproofing is required, use the KingDeck HPW system
About this system
KingDeck HPU System is a UV resistant, hard-wearing, polyurethane coating system primarily designed for use in car parks. It has excellent resistance to abrasion and wear and excellent chemical resistance to petrol, diesel, engine oil, brake fluid and de-icing salts.
Where to use
- Ramps and turning circles
- Traffic aisles and parking bays
- Pedestrian walkways