🌍 🌐 English
Protective Coatings

KingCoat EN100 System

High performance chemical resistant epoxy novolac lining.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Build-up

Applied in this order, from the substrate up. Layers drawn with a dashed outline are optional.

KingCoat EN100 System, layer by layer
KingCoat EN100 build-up Substrate12345
Not to scale. Thicknesses are shown for clarity.
No.ProductFunctionRate or thickness
SubstrateConcrete (laitance removed by grit blasting/water jetting) or steel (SA 2½) in chemical plants, sewage works, refineries, food areas
1 KingRep EP10 Optional Only to fill exposed blow holes during surface preparation Blow-hole filler
2 KingFloor Primer S Optional EN100 is designed for use without a primer. Primer S is only for highly porous substrates Primer 5 m²/kg
3 KingCoat EN100 Brush, short-nap roller or airless spray Epoxy novolac base coat 0.33 kg/m² (min 250 microns for the antislip finish)
4 KingFloor AS100 Optional Grade No. 2. Antislip finish only. Fully blinded into the base coat; excess removed after initial cure Broadcast aggregate 0.35-0.75 kg/m²
5 KingCoat EN100 Apply within the over-coating time (<18 h @ 23ºC) Epoxy novolac top coat 0.33 kg/m² (standard); 0.50 kg/m² / 400-750 microns (antislip)
Turn the build-up in 3D
Drag to turn. Click to separate the layers.

Build-up options

  • Standard coating: base coat 0.33 + top coat 0.33 kg/m²
  • Antislip: base coat 0.33 kg/m² + KingFloor AS100 No. 2 + top coat 0.50 kg/m², approx. 1.5 mm system
  • Glass-fibre reinforced lining: 250 micron wet coat + glass fibre mat pressed in + saturated with EN100, for high build and fine-crack bridging

About this system

KingCoat EN100 is a two-component seamless epoxy novolac coating designed for areas where excellent wear and chemical resistance is required. KingCoat EN100 is suitable for use on concrete and steel surfaces. The material may be used with or without antislip aggregates and can also can be laminated with glass fibre cloth to achieve a high build, chemical resistant lining.

Where to use

  • Chemical plants
  • Sewage treatment plants
  • Pharmaceutics industry
  • Petroleum refineries
  • Storage areas
  • Loading docks
  • Food processing areas