KingFloor WC300®
Solvent free flexible two component polyurethane floor coating.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
Overview
KingFloor WC300 is a solvent free flexible two component polyurethane based floor coating; it provides a fairly smooth surface. It has excellent resistance to petrol, battery acid, diesel, brake fluid, de-icing salts, etc. Other applications include walkways, balconies, etc. KingFloor WC300 is formulated for easy application by roller or brush with excellent resistance to abrasion and chemical attack.
KingFloor WC300 is available in two types:
- KingFloor WC300 for indoor applications.
- KingFloor WC300 for outdoor applications which is specifically formulated for colour stability and will not dis-colour on exposure to sunlight or UV light. It is available in a wide range of colours.
KingFloor WC300 can be supplied in a variety of colors and slip resistant finishes and can be produced for every demanding situation.
Where to use
Designed for interior use (KingFloor WC300 ) and exterior use (KingFloor WC300 Plus) in parking and public places such as:
- Car parks, traffic aisles and parking bays.
- Restaurants, hotels, and reception areas.
- Schools, colleges, and universities.
- Sports halls, gymnasiums and ramps.
- Retail environments and many more.
Why use it
- Excellent chemical resistance.
- Excellent resistant to petrol, battery acid, diesel and brake fluid.
- Resistant to de-icing.
- Flexible, can bridge minor cracks.
- UV resistant (KingFloor WC300 Plus).
Technical properties
Values @ 25°C
| Wear Coat | KingDeck Wear Coat Plus | |
|---|---|---|
| Appearance | Smooth gloss finish | |
| Colour | Wide range of colours | |
| Mixed density | 1.6 g/cm³ | 1.35 g/cm³ |
| Volume solids | 100% | |
| Mixing ratio By weight | B 82 : H 18 | B 67 : H 33 |
| Working time | 60 min | 20 min |
| Tack-free time | 4 hr | 8 hr |
| Maximum overcoat time | 24 hr | 30 hr |
| Full cure | 7 days | |
| Adhesion to concrete | > 1 MPa (Substrate failure) | |
| Adhesion to asphalt | > 1 MPa (Substrate failure) | |
| Tensile strength | 10 MPa | 9 MPa |
| Shore D hardness | 80 | 60 |
| Application temperature | Do not apply if the ambient or floor temperature is to fall below 5°C during the first 24 hours or if rain or condensation is likely | |
Concrete floors must have a minimum compressive strength of 25 N/mm² and a maximum concrete relative humidity of 70% (max. moisture content of 3%), relative humidity can be measured using a hygrometer. Concrete relative humidity should be less than 70% for concrete 28 days old or more.
How to use
Substrate preparation
The substrate must be clean, dry, even, dense and free from oil, grease, dust and other contaminants. A clean surface will ensure maximum adhesion between the substrate and the coating.
Surface preparation
Unsound layers and contaminated concrete surfaces must be prepared using mechanical surface removing equipment. Acid etching can be used only in well ventilated areas. Areas deeply contaminated by oil or grease, such areas should be treated by hot compressed air.
Priming
KingFloor WC300 is designed to be used without a primer. However, for highly porous substrates, KingFloor Primer (Solvent free epoxy primer) is recommended.
Mixing
KingFloor WC300 comprises two components, a resin and hardener, which are supplied pre-weighed in the correct proportions. Under no circumstances should part mixing be carried out.
Taking care to ensure that the bottom and sides are thoroughly scraped, transfer the entire contents of both components into a separate mixing container. Using a power whisk attached to a slow speed electric drill, mix for approximately 3 minutes ensuring the mixing head is pushed around the sides and bottom of the mixing container.
Important: Never mix KingFloor WC300 by hand as this could lead to areas of uncured material. Premixing of the resin component will aid mixing.
Application
On completion of mixing immediately apply KingFloor WC300 on two coats at the required thickness to KingFloor Primer.
SLIP RESISTANT FINISHES
Whilst the KingFloor Primer is still wet, completely blind it with an appropriate grade of Aggregate with a coverage rate of 0.5 - 0.8 kg/m².
Allow the Primer to cure for the specified time then vacuum off the excess aggregate. Then the KingFloor WC300 is applied on the Anti-slip substrate with the specified coverage rate.
REMARKS
- KingFloor WC300 should not be applied onto surfaces known to suffer from damp rising or RH greater than 70%.
- KingFloor WC300 should not be applied at temperatures below 8°C.
- For temperatures above 30°C the following steps need to be done:
- Material needs to be stored in a cool place away from direct sunlight.
- Equipments to be into direct contact with the material, needs to be cool.
- Application during the coolest time of the day is preferable.
Cleaning
Tools should be cleaned with KingKrete Solvent immediately after use.
Coverage, packaging and storage
Coverage
KingFloor Primer: 0.25 – 0.30 kg/m²/coat.
Wear Coat : 0.33 kg/m²/coat on a smooth surface; 0.60 kg/m²/coat on Anti-slip Aggregates for 1st coat and 0.40 kg/m²/coat on Anti-slip Aggregates when applying 2nd coat.
KingDeck Wear Coat Plus: 0.28 kg/m²/coat on smooth surfaces, 0.50 kg/m²/coat on Anti-slip Aggregates for 1st coat and 0.33 kg/m²/coat on Anti-slip Aggregates when applying 2nd coat.
Packaging
KingFloor WC300 is available in 5 and 15 kg packs.
KingFloor WC300 Plus is available in 5 and 15 kg packs.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.