KingFloor CP Seal®
Three component polyurethane cove pack sealer.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
Overview
KingFloor CP Seal is a three component water based polyurethane coating designed to be used in conjunction with KingFloor CP. KingFloor CP Seal is used to seal the semi-porous KingFloor CP providing a coloured seamless hygienic wall and floor system.
KingFloor CP Seal has very good resistance to many of the chemicals commonly found in industrial environment (consult our Technical Department for further details).
KingFloor CP Seal can be supplied in a range of colours (consult our Sales Department for further details).
Where to use
KingFloor CP Seal is designed for applications where high hygienic flooring is required with high resistance against impact, thermal shock, abrasion and chemicals.
KingFloor CP Seal is suitable for use in dairies, breweries, food processing areas, cold stores, freezer rooms, kitchens, etc. KingFloor CP Seal can be steam cleaned and is resistant to boiling water and process liquids.
Why use it
- Provides hygienic floors.
- Resistant to boiling water and to a wide range of chemicals (consult KINGKRETE Technical Department for more details).
- Hard wearing.
- Easy to clean.
- Resistant to freeze/thaw cycles.
Note: KingFloor CP Seal is not colour stable and may discolour on ageing and exposure to UV light, especially with light colours. This will not adversely affect the performance of the product.
Technical properties
Values @ 25°C
| Appearance | Matt finish |
|---|---|
| Color | Available in a range of colours |
| Mixed density | 1.45 ± 0.05 g/cm³ |
| Working time | 20 - 25 min @ 25°C 10 - 15 min @ 35°C |
| Tack-free time | 1 hr |
| Maximum overcoat time | 24 hr |
| Full cure | 7 days |
| Application temperature | 5 - 35°C |
| Maximum Wear depth: EN 13892-4 | 0.01 mm |
| VOCASTM 2369 | < 20 g/ltr |
How to use
Surface preparation
The surface of the KingFloor CP must be clean, dry and free of dust laitance, oils, paints or other forms of contamination prior to applying KingFloor CP Seal.
Priming
The KingFloor CP Seal does not need to go onto a primed surface.
Mixing
Mix the aggregate with resin component thoroughly to form a paste like consistency then add the hardener and continue to mix.
Important: Never mix KingFloor CP Seal by hand as this could lead to areas of uncured material.
KingFloor CP/ KingFloor Primer
Cove Pack Seal
KingFloor PUHD HD Substrate
Application
On completion of mixing, immediately apply KingFloor CP Seal by brush or roller to form a smooth and even coat. Apply second coat, if required, within overcoating time. Do not apply too thickly as this can lead to a reduced cure speed and inconsistency of colour.
Note: Never leave the mixed KingFloor CP Seal to stand for any length of time before application, as this will considerably shorten its working time.
Working Time
KingFloor CP Seal has a working time of approximately 20 to 25 minutes at 25°C.
Working Conditions
KingFloor CP Seal should not be applied at temperatures less than 5°C and not higher than 35°C.
Cleaning
Tools should be cleaned with water immediately after use.
Coverage, packaging and storage
Coverage
Approximately 3 – 5 m²/kg per coat onto the KingFloor CP.
Packaging
KingFloor CP Seal is available in 3 kg (2 ltr) packs.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
| Occassional Spillage. Chemical Resistance after full cure (28 days @ 25°C), ASTM D1308 (Spot - test @ 1 hr) | |
|---|---|
| Organic acids | |
| Lactic Acid 10% | R |
| Oleic Acid sat. | R |
| Citric Acid 25% | R |
| Acetic Acid 10% | R |
| Tartaric Acid 10% | R |
| Inorganic bases | |
| Sodium Hydroxide 40% | R |
| Ammonia Solution 10% | R |
| Potassium Hydroxide 50% | R |
| Aqueous solutions | |
| Sodium Chloride sat. | R |
| Chlorinated water | R |
| Solvents | |
| White spirit | R |
| Xylene | R |
| Oils & fuels | |
| Brake oil | R |
| Engine oil | R |
| Diesel | R |
| Petrol | R |
| Hydraulic oil | R |
| Inorganic acids | |
| Sulphuric Acid 25% | R |
| Phosphoric Acid 20% | R |
| Hydrochloric Acid 10% | R |
| Nitric Acid 10% | RS |
| Sugar flavourings | |
| Sugar Solution sat. | R |
| Glucose Syrup sat. | R |
| Carbonated beverages | |
| Pepsi/Coca Cola | R |
| Miranda/Fanta | R |
| 7UP | R |
| Electrochemical solutions | |
| Copper Sulphate 1M | R |
| Zinc Sulphate 1M | R |
| Fruit juices | |
| Orange juice | R |
| Apple juice | R |
| Lemon juice | R |
| Fats | |
| Vegetable oil | R |
| Cleaning aids | |
| Dish washing liquid | R |
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.