KingSeal CS100®
EPDM and Neoprene Joint Membranes and Seals.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Tensile strength ISO 37
- 100 kg/cm²
- Elongation at break ISO 37
- 300 %
- Hardness ISO 7619
- 70 - 75
- Specific gravity ISO 2781
- 1.18 ± 0.05
Overview
KingSeal CS100 is a range of joint membranes and seals specifically designed for demanding applications in expansion joints. The range is made of premium quality EPDM and optional neoprene (Chlorinated Rubber) sections.
Where to use
- Parking Structures Joints.
- Floor to floor and floor to wall joints.
- Roof and open space joints.
Why use it
- Waterproof.
- Available in a number of sizes to fit requirements.
- Corrugations and perforations for mechanical fixation.
- High movement accommodation.
- Absorbs impact loads.
Technical properties
| HardnessISO 7619 | 70 - 75 |
|---|---|
| Specific gravityISO 2781 | 1.18 ± 0.05 |
| Tensile strengthISO 37 | 100 kg/cm² |
| Elongation at breakISO 37 | 300 % |
| Compression setISO 815 (24 hr @ 100°C) | 35 % |
How to use
Method of use
Concrete surfaces shall be fully cured and free from all contaminants and weak material. Recesses shall be prepared at a 10 cm width and 1.5 cm height along the joint. Prepared recesses need to be mechanically abraded to remove any laitence or contaminants.
Position KingSeal CS100 over the joint, optionally prime the joint edges with KingPrimer CS using a brush. Compress the bottom of the seal to insert it into the joint then use KINGKRETE insertion tool to push the seal firmly into the joint in a manner where the seal flaps are laying flat on the recess.
Apply a masking tape on the recess edges. Apply KingInject ETS as per separate datasheet instructions, once applied and finished remove the masking tape and allow to cure.
In case of floor to wall slab, seal flaps need to be fixed mechanically using screws on a bed of a single component polyurethane sealant and adhesive such as KingSeal PU140.
Please refer to KINGKRETE technical department for a detailed Method statement of application.
Cleaning
KingSeal CS100 can be cleaned using an industrial grade solvent such as Xylene or MEK. KingInject ETS and KingSeal PU140 are cleaned from tools by Xylene.
Coverage, packaging and storage
Packaging
KingSeal CS100 are preformed and cut to length as per the maximum limits allowed by transport and UN specifications.
MOVEMENT TABLE
| Installation Width | Joint Opening “A” | ||||
|---|---|---|---|---|---|
| Model No. | Min (mm) | Max (mm) | Min (mm) | Max (mm) | Total |
| CS301 | 25 | 51 | 19 | 57 | 38 |
| CS302 | 44 | 70 | 32 | 96 | 44 |
| CS303 | 54 | 95 | 38 | 102 | 65 |
| CS304 | 67 | 121 | 44 | 127 | 83 |
| CS305 | 76 | 146 | 51 | 152 | 102 |
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.