KingDeck EW System®
Solvent free slip resistant flexible waterproofing polyurethane vehicle decking system.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
Overview
KingDeck EW System is a hard wearing, solvent free, flexible polyurethane coating system primarily designed for use in car parks. It has excellent resistance to petrol, battery acid, diesel, brake fluid, de-icing salts, etc. KingDeck EW System is formulated for easy application by squeegee, roller or brush.
The KingDeck EW System consists of three layers:
Primer
- KingDeck PC100 or KingDeck Primer PU (depending on concrete/ substrate age), primers with excellent adhesion to concrete, screed and asphalt substrates.
Waterproofing Intermediate Coat + Anti-slip
- KingDeck FC100, an elastomeric crack-bridging membrane.
- KingDeck Primer PU, PU primer to be applied directly on the KingDeck FC100 with full blind of Antislip Aggregate, a hard-wearing quartz for producing an anti-slip finish.
Topcoat
- KingDeck WC200 TG, for indoor application, a pigmented wearing course with excellent resistance to abrasion and chemical attack.
- KingDeck WC200 Plus, for outdoor application, specifically formulated for colour stability and will not discolour on exposure to sunlight or other sources of UV light. It is available in a wide range of colours.
Where to use
KingDeck EW System is designed for use in applications, such as:
- Car park decks.
- Car park ramps and turning circles.
- Traffic aisles and parking bays.
Why use it
- Seamless and “watertight”
- Excellent resistant to petrol, battery acid, diesel and brake fluid.
- Resistant to de-icing.
- Available in a special grade “KingDeck WC200 Plus” for outdoor applications.
Fire resistant system.
- Reduces noise.
- Up to 3.9 mm crack bridging ability for full system.
- Slip resistant.
- Suitable for asphalt and concrete substrates.
SYSTEM SPECIFICATION
The combination of products specified depends on the area within the car part to which the KingDeck is being applied.
CAR PARKS DECKS
Ramps and turning circles
- KingDeck PC100 or KingDeck Primer PU.
- KingDeck FC100 to achieve waterproofing properties.
- KingDeck Primer PU + full blind of Anti-slip Aggregates #2.
- 2 coats KingDeck WC200 TG (indoor) or WC200 Plus (outdoor).
- Dry film thickness ≈ 2.4 mm for both indoor and outdoor.
Traffic aisles and parking bays
- KingDeck PC100 or KingDeck Primer PU.
- KingDeck FC100 to achieve
- waterproofing properties.
- KingDeck Primer PU + full blind of Anti-slip Aggregates #3.
- 1 coat KingDeck WC200 TG (indoor) or WC200 Plus (outdoor).
- Dry film thickness ≈ 1.9 mm for both indoor and outdoor.
KingDeck WC200 TG or Plus.
KingDeck Primer PU + full blind of Anslip aggregates.
KingDeck FC100.
KingDeck PC100 or KingDeck Primer PU.
Concrete
Technical properties
Values @ 25°C
| Crack BridgingASTM C957 | Passes (full system test) |
|---|---|
| Abrasion resistance (1000 g, 1000 cycle) weight loss CS17ASTM C957 (KingDeck PC100/KingDeck FC100/KingDeck Primer PU/WC200 Plus) | Passes |
| Weight lossASTM C957 (KingDeck FC100) | Passes |
| Adhesion peelASTM C957 (KingDeck PC100/KingDeck FC100) | Passes |
| Slip resistance – typical figures: BS 7976, Part 2:2002 | Coarse Quartz Aggregate blind TRL slider: 84 dry, 72 wet; 4-S slider: 61 dry, 53 wet |
| External fire exposure roof test: BS 476, Part 3:1958 | EXT.F.AA (full system test) |
Standards and approvals
KingDeck FC100 complies with ASTM C957 (See technical properties).
How to use
Method of use
KingDeck Primcoat E or PU
Surface Preparation and Priming
To obtain a proper bond the substrate must be structurally sound clean, dry (less than 75% RH measured using a hygrometer, unless it is a suspended deck free to dry from below) and free from dust, laitance, oils, paints or other forms of contamination.
Grit blasting, grinding or scarification can be used to remove laitance and surface contamination. Areas known to have been subject to heavy contamination should be thoroughly inspected before applying KingDeck PC100. This is especially important where deposits of oil or grease have collected. Any irregularities within the substrate should be made good before the application of the KingDeck PC100 or KingDeck Primer PU. Small defects may be repaired using KingDeck PC100 or KingDeck Primer PU mixed with dry fine sand. KingDeck PC100 is less sensitive than KingDeck Primer PU for the concrete age. KingDeck PC100 or KingDeck Primer PU will give good adhesion with concrete substrates if the concrete is with longer age.
If the substrate has a relative humidity reading greater than 75%, 2 coats of KingFloor Primer DPM should be used, followed by KingFloor Primer fully blinded with Medium Quartz Aggregate, before coating with KingDeck PC100 or KingDeck Primer PU.
Surface preparation (KingDeck PC100)
All surfaces should be primed with KingDeck PC100 or KingDeck Primer PU before applying KingDeck FC100. Application of KingDeck FC100 should be carried out within 30hours from applying KingDeck PC100 or KingDeck Primer PU.
Mixing (KingDeck FC100)
KingDeck FC100 comprises two components, a resin and hardener which are supplied pre-weighed in the correct proportions. Under no circumstances should part mixing be carried out. Pre-mix the resin component with a power whisk attached to a slow speed electric drill for 1 minute before mixing both components. Taking care to ensure that the bottom and sides are thoroughly scraped, transfer the contents of the resin in to the hardener.
Using a power whisk attached to a slow speed electric drill, mix for approximately 3 minutes, ensuring the mixing head is pushed around the sides and bottom of the mixing container. Transfer the contents into another container, scraping down and re-mixing for a further 2 minutes avoiding the entraining of excessive air until a uniform consistency is obtained.
Note: Never mix KingDeck FC100 by hand as this could lead to areas of uncured material. Select an appropriate mixing container that will allow proper and efficient mixing.
Application (KingDeck FC100)
Immediately after mixing is complete, spread the KingDeck FC100 onto the primed floor using a squeegee and finish using a short or medium pile roller. KingDeck FC100 is not colour stable and changes may be seen following application and before overcoating. This will not affect the properties of the KingDeck FC100 in any way.
OVER COATING
KingDeck FC100 may be overcaoted as soon as it becomes tack free with a maximum overcoat time of 30 hours. Then apply KingDeck Primer PU and full blind with Antislip Aggregate.
KINGDECK WC200 TG OR WC200 PLUS
Surface preparation (KingDeck WC200)
Before applying the final KingDeck WC200 TG or Plus, all surfaces coated with KingDeck FC100 should be primed with KingDeck Primer PU and fully blinded with Anti-slip Aggregates at the rate of 2 - 3 kg/m² and allow to dry. All excess aggregates shall be removed before applying the topcoat.
Mixing (KingDeck WC200)
KingDeck WC200 TG or Plus comprises two components, a resin and hardener, which are supplied pre-weighed in the correct proportions. Under no circumstances should part mixing be carried out.
Taking care to ensure that the bottom and sides are thoroughly scraped, transfer the entire contents of both components into a separate mixing container. Using a power whisk attached to a slow speed electric drill, mix for approximately 3 minutes ensuring the mixing head is pushed around the sides and bottom of the mixing container.
Note: Never mix KingDeck WC200 TG or Plus by hand as this could lead to areas of uncured material. Premixing of the resin component will aid mixing.
Application (KingDeck WC200)
On completion of mixing immediately apply the KingDeck WC200 TG or Plus at the required thickness to the blinded KingDeck Primer PU.
Mixing (KingDeck PC100)
KingDeck PC100 or KingDeck Primer PU comprises two components; a resin and hardener which are supplied pre-weighed in the correct proportions. Under no circumstances should part mixing be carried out. Taking care to ensure that the bottom and sides are thoroughly drained, pour the contents of the hardener portion into the resin container. Using a power whisk attached to a slow speed electric drill, mix for approximately 2 minutes, scrape down and re-mix for a further 1 minute, avoiding the entraining of excessive air, until a uniform consistency is obtained.
Allow to stand for 1 minute. If the filler is to be used, add this to the mixed material and mix for a further 1 minute.
Note: Never mix KingDeck PC100 or KingDeck Primer PU by hand as this could lead to areas of uncured material.
| System component | KingDeck PC100 | KingDeck Primer PU | KingDeck FC100 | WC200 TG | WC200 Plus |
|---|---|---|---|---|---|
| Working time | 180 min | 40 min | 25 min | 60 min | 20 min |
| Mixed density | 1.1 g/cm³ | 1.25 g/cm³ | 1.3 g/cm³ | 1.6 g/cm³ | 1.35 g/cm³ |
| Volume solids | 100% | ||||
| Tack-free time | 12 hr | 3 hr | 5 hr | 4 hr | 8 hr |
| Maximum overcoat time | 36 hr | 24 hr | 4 hr | 30 hr | |
| Full cure | 7 days | 3 days | 7 days | ||
| Adhesion to concrete | > 1.0 MPa (substrate failure) | ||||
| Adhesion to asphalt | > 1.0 MPa (substrate failure) | ||||
| Tensile strength @ 7 days: ASTM D412 | Not tested | > 6 MPa | > 12 MPa | > 11 MPa | |
| Elongation @ 7 days: ASTM D412 | Not tested | > 500% | > 65% | > 40% | |
| Shore D hardness @ 7 days: ASTM D2240 | Not tested | 80 | 30 | 75 | 65 |
| Taber abrasion resistance: (1000 g, 1000 cycle)ASTM D4060, weight loss CS17 wheel | Not tested | 90 mg | 70 mg | ||
| Application temperature range | Do not apply if the ambient or floor temperature is to fall below 5°C during the first 24 hours or if rain or condensation is likely) | ||||
| COVERAGE | ||||
|---|---|---|---|---|
| Application | Indoor | Outdoor | Indoor | Outdoor |
| Ramps & turning circles | Traffic aisles & parking bays | |||
| KingDeck PC100 or KingDeck Primer PU | One coat 0.25 - 0.30 kg/m² per coat | |||
| KingDeck FC100 | One coat 1.00 kg/m² per coat | One coat 0.70 kg/m² per coat | ||
| KingDeck Primer PU | One coat 0.30 - 0.40 kg/m² per coat | |||
| Antislip #2 or #3 | #2 Aggregate (fully blinded) 2 - 3 kg/ m² | #3 Aggregate (fully blinded) 2 - 3 kg/ m² | ||
| WC200 TG | Two coats 0.60 kg/m² for 1st coat 0.40 kg/m² for 2nd coat | One coat 0.60 kg/m² per coat | ||
| WC200 Plus | Two coats 0.50 kg/m² for 1st coat 0.33 kg/m² for 2nd coat | One coat 0.50 kg/m² per coat | ||
| System thickness | 2.4 mm | 1.9 mm | ||
Application (KingDeck PC100)
Once mixing is complete, spread the KingDeck PC100 or KingDeck Primer PU onto the floor using a squeegee and/or medium pile roller, ensuring it is worked well into the surface.
OVER COATING
KingDeck PC100 or KingDeck Primer PU may be overcoated as soon as it becomes tack free. If overcoating of the KingDeck PC100 or KingDeck Primer PU exceeds 30 hours, light scarification of the surface should be undertaken before further applications of any subsequent layer.
KINGDECK FC100
Cleaning
Tools should be cleaned with KINGKRETE Solvent immediately after use.
Coverage, packaging and storage
Packaging
KingDeck PC100 and KingDeck Primer PU are available in 5 and 20 kg packs.
KingDeck FC100, WC200 TG and WC200 Plus are available in 5 and 15 kg packs.
Anti-slip Aggregates #2 and #3 are available in 25 kg bags.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.