KingFloor AS200®
Water based polyurethane anti-slip/sealer for concrete, cement screeds, resin, vinyl, wood, and parquet floors
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Pot life
- > 3 hr @ 250C
- Mixed density
- 1.063 g/cm3 @ 25°C
- Mixed viscosity
- 57cP @ 25°C
Overview
A KingFloor AS200 is a two component water based polyurethane anti-slip/sealer that works very effectively on internal smooth concrete, special cement screeds, wood, parquet, vinyl floorings, epoxy and polyurethane based floor coatings.
KingFloor AS200 provides a matt finish and protects floors from stains left behind from spillages (See chemical resistance table).
Where to use
KingFloor AS200 is designed for internal use in public places such as:
- Restaurant and hotel kitchens.
- Reception areas, sanitary hospital, retail stores, warehouses, and showrooms.
- Office buildings, schools, colleges, and universities.
- Sports halls, exhibition centers gymnasiums, ramps and locker rooms.
- Retail environments, shopping malls and many more.
Why use it
- Safer floors, less risk of slips or falls.
- Outstanding slip resistance; up to 50 - 60 Wet Pendulum Test Value can be reached.
- Provides excellent stain resistance.
- Rapid drying time, permits faster use of floors.
- Excellent durability.
- Slight modification of the surface roughness of the substrate; A good cleaning regime will not be different to that prior to treatment.
- Easy to maintain and to clean.
- UV Resistant (internal lighting).
Technical properties
| Appearance | Matt |
|---|---|
| Colour | Clear |
| Mixed density | 1.063 g/cm3 @ 25°C |
| Mixed viscosity | 57cP @ 25°C |
| Pot life | > 3 hr @ 250C |
| Solid Content | |
| By volume | 36% |
| By weight | 40% |
| Recommended film thickness | |
| Concrete & screeds | 160 - 200 microns wet (2 coats) 60 - 70 microns dry (2 coats) |
| Non-porous substrates | 80 - 100 microns wet (1 coat) 30 - 35 microns dry (1 coat) |
| Drying time | 30 - 40 min @ 25°C |
| Time between coats | Minimum 2 hr |
| Light traffic (after second coat) | After 12 hr |
| Full cure | 72 hr |
| Bond strength (to KingFloor EP100 and KingFloor SL350ASTM D4541 | >2 MPa (concrete failure) |
| Taber abrasion resistance (1000g, 1000 cycle) ASTM D4060, weight loss CS17 wheel | 24 mg |
- KingFloor AS200 is not recommended for use on ceramic
- tiles, stone.
- Do not leave standing water on fully cured KingFloor AS200 coat applied over concrete or cement screed for more than 2 hours.
Standards and approvals
KingFloor AS200 complies with requirements of HSE Risk Assessments for Floor Safety when tested according to BS 7976-2:2002 and BS 13036-4:2011.
How to use
Method of use
Substrate Preparation
The substrate should be clean and free from contamination.
Concrete and screed floors
Clean concrete and screeds with a propriety cleaner.
Resin and vinyl floors
Clean vinyl floorings, resin based floor coatings using the appropriate cleaning method used for each substrate.
Wood and parquet flooring
Surfaces need to be lightly sanded prior to application.
Mixing
KingFloor AS200 comprises two components, a resin (Base “B”) and Hardener “H”, which are supplied pre-weighed in the correct proportions. Under no circumstances should part mixing be carried out.
The anti-slip beads may settle out in storage. Care should be taken to ensure that beads are scrapped and mixed thoroughly with the resin in the base component. Ensure the mixing head is pushed around the sides and bottom of the mixing container prior to the inclusion and mixing with the hardener.
Taking care to ensure that the bottom and sides are thoroughly drained, pour the contents of the hardener component (H) into the base (B) container. Using a power whisk attached to a slow speed mixer (100 – 300 rpm), mix for approximately 3 - 5 minutes ensuring the mixing head is pushed around the sides and bottom of the mixing container.
Application
KingFloor AS200 is applied in thin coats by medium pile lambs wool roller. It is recommended to apply two coats of KingFloor AS200 at the stated rate of application.
Pendulum Test Values (PTV): BS EN 13036-4 on different types of floors
| Health & Safety Executive Guidelines | Wet before KingFloor AS200 | Wet After KingFloor AS200 | |
|---|---|---|---|
| Floors coated by epoxy and polyurethanes, etc. | ≥ 36 PTV | 8 - 20 PTV | 50 - 60 PTV |
| Vinyl floors | ≥ 36 PTV | 24 - 28 PTV | 50 - 55 PTV |
| Melamine based laminates | ≥ 36 PTV | 12 - 18 PTV | 50 - 55 PTV |
| Wood and parquet floors | ≥ 36 PTV | 15 - 20 PTV | 50 - 60 PTV |
| Concrete and cement screed | ≥ 36 PTV | 15 - 20 PTV | 48 - 50 PTV |
Occassional Spillage.
Chemical Resistance after full cure (7 days @ 25°C), ASTM D1308 (Spot - test @ 1 hr)
| Organic Acids | |
|---|---|
| Oleic Acid (Saturated) | R |
| Citric Acid 10% | R |
| Vinegar 5% | R |
| Inorganic Bases | |
| Sodium Hydroxide 50% | R |
| Ammonia Solution 10% | R |
| Potassium Hydroxide 50% | R |
| Aqueous Solutions | |
| Sugar Solution (Saturated) | R |
| Sodium Chloride (Saturated) | R |
| Tap Water | R |
| Distilled Water | R |
| Chlorinated Water | R |
| Dead Sea Water | R |
| Solvents | |
| White Spirit | SS |
| Xylene | SS |
| Toluene | SS |
| Methyl Ethyl Ketone | SS |
The second coat should be applied at a right angle to the first coat within the minimum and maximum overcoating time to achieve the maximum adhesion between the two coats.
Cleaning
All tools should be cleaned immediately after application with KingKrete Solvent. Hardened materials must be cleaned mechanically.
Limitations and notes
Limitations
- Some proprietary cleaners are not suitable; KINGKRETE Technical department should be contacted for advice.
- KingFloor AS200 is not recommended to be applied on sealers unless adhesion and peel off tests are performed.
Notes
Never leave the mixed KingFloor AS200 to stand for any length of time prior to application as this will considerably shorten its working time.
Do not apply KingFloor AS200 in temperatures less than 10°C.
Contact KINGKRETE Technical Department for further details.
Coverage, packaging and storage
Coverage
Approximately 50 - 60 m²/pack/coat.
Packaging
KingFloor AS200 is supplied in 4.5 litre packs for resin "B" component and 400 ml packs for hardener "H" component.
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.
Chemical Resistance Continued
| Oils & Fuels | |
|---|---|
| Benzyl Alcohol | R |
| Brake Fluid | R |
| Engine Oil | R |
| Diesel | R |
| Kerosene | R |
| Detergents & Soaps | R |
| Inorganic Acids | |
| Sulphuric Acid 10% | R |
| Phosphoric Acid 20% | R |
| Hydrochloric Acid 32% | R |
| Nitric Acid 10% | R |
| In Food Processing Areas | |
| Vegetable Oil | R |
| Ketchup | R |
| Mayonnaise | R |
| Coffee | R |
| Tea | R |
| Milk | R |
| Fruit juice | R |
| Cola | R |