🌍 🌐 English
Joint Sealants

KingSeal C50®

Elastomeric acrylic cement mortar sealant.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Tensile strength ASTM D412
> 0.95 MPa @ 7 days
Elongation at break ASTM D412
> 110% @ 7 days
Shore A Hardness ASTM D2240
75 ± 5 @ 28 days
Pot life @ 25°C
60 - 90 min

Overview

KingSeal C50 is a two component polymer modified cementitious tough sealant suitable for sealing joints and cracks in concrete, pre-cast elements, mortars and bricks.

Where to use

KingSeal C50 is ideally designed for use in the following applications:

  • Sealing all types of cracks in concrete and masonary.
  • Sealing joints with anticipated movement up to 5%.
  • Sealing joints between pre-cast elements for both horizontal and vertical application.
  • Sealing joints in water retaining structure.

Why use it

  • Excellent slump resistant up to 3 cm wide on vertical surfaces.
  • Weather resistance.
  • Can accomodate movement up to 5%.
  • Can be over painted.
  • Non-toxic, suitable for use inside potable water tanks.
  • Bonds to damp concrete.
  • Good impact and tear resistant sealant.

Technical properties

ColourGrey
Mixed density1.5 ± 0.1 g/cm³
Shore A HardnessASTM D224075 ± 5 @ 28 days
Maximum aggregate
size: ASTM E011
0.3 mm
Pot life @ 25°C60 - 90 min
Tensile strengthASTM D412> 0.95 MPa @ 7 days
Elongation at breakASTM D412> 110% @ 7 days
Application temperature5 - 35°C
Service temperature-20 to 70°C

The full powder bag is then added slowly to liquid while mixing continuously with low speed mixer/drill (400 - 600 rpm). Mixing time should be continued for 3 minutes until a uniform consistency is obtained.

PLACING AND FINISHING

The mixed mortar shall be applied directly into the damped joints by trowel or putty knife and smoothed to the disred finish.

To enhance bonding of mortar to joint sides, the white liquid polymer can be applied by brush on the joint edges and while still tacky the mixed KingSeal C50 is applied.

JOINT SIZE SUITABILITY

Joint width:

  • 3 mm minimum.
  • 30 mm maximum.

Joint depth:

  • 3 mm minimum.
  • 15 mm maximum.

How to use

Joint preparation
  • The joint surfaces must be clean, free from contamination and curing compound.
Priming

Prior to applying KingSeal C50, all joints must be dampened with water till a surface saturation dry condition is reached. All excess water should be removed prior to KingSeal C50 application.

Yet to improve bonding, the white liquid polymer can be applied by brush on joint edges, and while still tacky, the mixed KingSeal C50 is applied.

Mixing

To ensure proper mixing, a mechanically powered mixer or drill fitted with suitable paddle should be used.The white liquid should be added to a clean container.

Curing

Curing time varies depending on ambient temperature and relative humidity but normally 7 days should be enough. If KingSeal C50 is subjected to water submersion, then allow for 2 - 3 weeks of curing time.

Notes: KingSeal C50 should not be applied to frozen substrates or if ambient temperature is expected to fall below 5°C.

Cleaning

All tools should be cleaned immediately after finishing with water. Hardened materials can be cleaned mechanically.

Coverage, packaging and storage

Coverage

(Linear meter per 15 kg pack)

Width/Depth6 mm10 mm20 mm30 mm
6 mm280167
10 mm10050
15 mm22

Packaging

KingSeal C50 is available in 15 kg packs (10 litres). (5 kg white liquid and 10 kg powder).

Storage

Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.

Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.

Health and safety

As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.

Request the safety data sheet