🌍 🌐 English
Waterproofing

KingProof PVL®

High-performance, pre-applied, loose-laid PVC membrane for below-grade waterproofing.

SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.

Overview

KingProof PVL is a high-quality, homogeneous, flexible PVC waterproofing membrane manufactured from plasticised PVC. It features a light-coloured signal layer on the top surface and is specifically developed for use in underground structures. The membrane is installed loose-laid and welded with hot air to create a watertight, continuous system.

Where to use

KingProof PVL is designed for the waterproofing of a wide range of elements, including:

  • Tunnels
  • Foundations and retaining walls
  • Vertical and horizontal sealing of below-grade structures
  • Terraces
  • Covered or protected roof applications

Why use it

  • Excellent mechanical properties
  • High resistance to micro-organisms and root penetration
  • Light-coloured top layer allows quick, reliable visual inspection during installation
  • Flexible at cold temperatures
  • Strong joints achieved through hot-air welding
  • Recyclable, with a low carbon footprint
  • No open-flame welding, enhancing safety during installation

Technical properties

PVL-1.5PVL-2.0PVL-2.5PVL-3.0
Thickness (EN 1849-2)1.5 ±5% mm2.00 ±5% mm2.50 ±5% mm3.00 ±5% mm
Signal-layer thickness (EN 1849-2)0.2 mm
Visible defects (EN 1850-2)No visible defects (Pass)
Dimensional stability (EN 1107-2)≤ 2%
Resistance to static load (EN 12730)20 kg
Tensile strength L/T (EN 12311-2 B)15 / 15 N/mm²17 / 16 N/mm²16 / 16 N/mm²16 / 16 N/mm²
Elongation at break L/T (EN 12311-2 B)250 / 250%300 / 300%300 / 300%300 / 300%
Tear resistance, nail shank (EN 12310-1)250 N360 N360 N500 N
Joint shear resistance (EN 12317-2)800 N/50 mm
Joint peel resistance (EN 12316-2)180 N/50 mm200 N/50 mm200 N/50 mm250 N/50 mm
Resistance to impact (EN 12691)800 mm1000 mm1000 mm1000 mm
Foldability at low temperature (EN 495-5)-25°C-25°C-25°C-30°C
Water permeability / tightness (EN 1296 / EN 1928, 7 bar)Waterproof
Water tightness under pressure (DIN 16726)Impermeable

Standards and approvals

KingProof PVL complies with EN 13967 and EN 13491, as per the technical properties table.

How to use

Method of use

KingProof PVL must be installed by experienced and qualified personnel.

Surface Preparation

Ensure all substrates are solid, clean and free of debris, sharp edges or voids. The blinding concrete should be finished with a steel trowel to achieve a smooth surface, and all corners and edges shall be rounded to a minimum radius of 50 mm. Any protrusions shall be removed by chiselling and grinding; nails, wires, loose stones and other obstructions shall be cleared, and all voids, service openings and holes filled to match the surrounding substrate level.

Separation / Protection Layers

A geotextile cushion layer weighing no less than 350 g/m² shall be installed directly over the blinding concrete. The geotextile is laid loosely and positioned to provide a minimum overlap of 100 mm between adjacent sheets, ensuring full coverage of the underlying blinding concrete.

Application

The layout and direction of membrane installation should take into account the irregular shape and geometry of the slabs to ensure proper coverage and continuity. Cut the PVC membrane to the required lengths, maintaining a minimum overlap of 80 mm between sheets, then unroll and position it carefully so it can connect properly with the vertical waterproofing. Where applicable, weld the membrane to the pile-head PVC waterstop by at least 30 – 40 mm, leaving 10 – 15 mm of the waterbar exposed above the weld.

Overlap seams must be no less than 80 mm, with the final welded seam width exceeding 30 mm for single-seam welds. Before welding, all surfaces must be thoroughly cleaned and confirmed dry and free from dust, oil, grease or contaminants. Once welding is complete, inspect and test all joints to confirm their integrity and proper adhesion.

Quality and care

All products originating from KingKrete’s facility are manufactured under a management system independently certified to conform to the requirements of the quality standards ISO 9001, ISO 14001 and ISO 45001.

Limitations and notes

Notes

Field service, where provided, does not constitute supervisory responsibility. For additional information contact your local KingKrete representative. KingKrete Inc. reserves the right to have the true cause of any difficulty determined by accepted test methods.

Remarks

KingProof PVL is not compatible with bitumen and must be protected against UV.

Coverage, packaging and storage

Packaging

PVL-1.5PVL-2.0PVL-2.5PVL-3.0
Thickness1.5 mm2.0 mm2.5 mm3.0 mm
Width2.2 m (+1%)
Length20 m

Storage

KingProof PVL has a shelf life of 18 months from the date of manufacture when stored in the original packaging at temperatures between 5°C and 30°C, kept dry and protected from direct sunlight, snow, ice, water and heat sources. Do not stack sharp items or additional pallets on top of the membrane during transport and storage.

Health and safety

KingProof PVL is not directly associated with any known hazard during normal use. As with all construction products, avoid contact with the eyes and skin and use in well-ventilated areas. For further information, refer to the Safety Data Sheet.

Request the safety data sheet