KingFiber CP System®
Heavy duty carbon fibre reinforced polymer plate structural strengthening system.
SpecWorld has the Spec Pack, CSI specification and drawings for registered specifiers.
- Compressive strength: ASTM D695
- ≥ 70 MPa @ 7 days
- Tensile strength: ASTM D638
- ≥ 27 MPa @ 7 days
- Pot life (F.I.P.)
- 25 min @25°C
Overview
Heavy duty structural strengthening system based on carbon Fibers, the KingFiber CP System100 series is a number of products based on CFRP plates for use with reinforced concrete, masonry, stonework, aluminum and timber. The system is composed of CFRP plates and an epoxy adhesive to bond reinforcement (KingRep EP20).
Where to use
To strengthen structures for:
1. Structure use change (load variations)
- Increase of live and dead loads.
- Increase in traffic (dynamic loads).
- Installation of industrial equipment and machinery.
2. Design or Construction Defects
- Insufficient structural members dimension.
- Lack of reinforcement steel.
3.Standards and Specifications Regulatory change
- Seismic design requirements.
- Design loading standards change.
- Change in design approach.
- Statutory regulations change.
4. Serviceability Improvement
- Crack control.
- Deflection and deformation decrease.
- Steel reinforcement stress reduction.
5. Structural Repair
- Structure renovation due to aging.
- Corrosion of reinforcement.
- Impact damage.
- Natural disaster damage.
6. After construction changes
- Openings in structural members.
- Removal of bearing members.
Why use it
- Ease of installation – cost effective.
- Preservation of space management (thin dimensions).
- Ease of jointing and forming.
- Ease of transportation.
- Available in a number of properties supporting ease of design.
- No corrosion and high alkali resistance.
- Extremely high strength.
Technical properties
(KINGFIBER CP SYSTEM)
| Base | High strength carbon Plate laminate | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Colour | Black | ||||||||||
| Fiber volumetric content | > 68% | ||||||||||
| E-modulus Tensile strength (Minimum) Mean value of tensile strength Elongation at break |
|
(KINGREP EP20)
| Appearance | Thick grey paste |
|---|---|
| Compressive strength: ASTM D695 | ≥ 70 MPa @ 7 days |
| E-Modulus (compression): ASTM D695 | ≥ 12000 MPa @ 7 days |
| Tensile strength: ASTM D638 | ≥ 27 MPa @ 7 days |
| Adhesive strength: ASTM D4541 | ≥ 3.5 MPa (concrete failure) |
| Pot life (F.I.P.) | 25 min @25°C |
| Mixing ratio | 1 : 3.6 |
| Slant shear bond strength: (old/ new concrete) AASHTO T-237-73 | ≥ 25 MPa |
| Heat deflection: ASTM D648 | ≥ 50°C |
Standards and approvals
KingFiber CP System designs are conducted as per ACI 440, FIB 14, and ISIS # 3, 4, 5.
How to use
Method of use
Design notes
No plastic deformation reserve is allocated to KingFiber CP System, thus the maximum bending resistance of a strengthened section is reached when plate failure occurs during steel yield and before concrete failure.
The mode of failure is influenced by the plate cross- section. To limit crack widths and deformation, the yield point should not be reached in the reinforcing bards under service conditions. Any shear surface and shearing of the laminate. Stress and deformation calculations can be made by the normal methods. They should be verified in accordance with standards SIA 160 (1989) and 162
(1989).
When assessing the condition of the structure; check the dimensions (geometry, reinforcement, evenness of surface to be strengthened), quality of existing construction materials, ambient climatic conditions, and agreed conditions of service.
Verifications to take place are:
Loading Safety: shearing of plates, anchorage, and non- strengthened structure (with allowance for a reduce safety factor Ɣ ≥ 1.0
Fatigue Resistance: check on concrete and steel stresses. Serviceability: Deformation with average strains, assuming elastic behavior of the structure and time based strain changes in concrete. Steel stresses (no plastic deformation in service conditions), and crack widths (by limiting the steel stresses under service conditions).
Substrate Preparation
All substrates shall be free from oil, grease or any contaminants. It is recommended to blast clean substrates and clean all debris or dust.
The substrate should be even and checked with a flat metal edge, the tolerance accepted shall not exceed 10 mm in a 2 m length.
MIXING OF KINGREP EP20
To ensure proper mixing, a mechanically powered mixer or drill fitted with a suitable paddle should be used.
Stir the base and the hardener individually to disperse any settlement. Entire contents of the base and hardener should be poured into a suitable size container and mixed mechanically for 3 minutes.
APPLICATION OF KINGFIBER CARBON PLATES
All pinholes, honeycombs, or surface irregularities on the concrete surface shall be treated and evened out using KingRep EP20 epoxy putty and leveling compound.
Use KingRep EP20 to bond the carbon plates by placing it on the KingFiber carbon plate after cleaning from the grinded side. Use a spatula for the placement and make sure that sufficient material is placed on the carbon plate.
Apply a thin layer of KingRep EP20 on the prepared substrate. Then apply the fiber plate with the KingRep EP20 onto the substrate.
Use a small roller to roll the plate till the excessive adhesive is pushed out from the sides of the plate and remove the excess with a spatula.
When KingFiber plates are intersecting, the bottom plate is to be ground in the crossing zone and cleaned prior to the application of the top layer.
Allow the adhesive to cure for 7 days prior to installing further renders or coatings. The expected consumption of KingRep EP20 per metre of plate at 2.0 mm thickness (typically 1.4 - 1.5 kg/m² per mm) is as follows:
| Width of Plate (mm) | KingRep EP20 (kg/m) @ 2 mm thickness |
|---|---|
| 50 | 0.15 |
| 60 | 0.17 |
| 80 | 0.23 |
| 90 | 0.26 |
| 100 | 0.29 |
| 120 | 0.35 |
| 150 | 0.44 |
Cleaning
KingRep EP20 and equipment can be cleaned with an industrial grade solvent.
Coverage, packaging and storage
Packaging
KingFiber CP System plates come in rolls of 100 m length.
KingRep EP20 is packaged in twin component packs of 15 kg.
AVAILABILITY
| KingFiber CP100 E-Modulus 165 GPA | ||
|---|---|---|
| Product no. | Width (mm) | Thickness (mm) |
| CP120 | 20 | 1.2 mm |
| CP121 | 20 | 1.4 mm |
| CP122 | 50 | 1.2 mm |
| CP123 | 50 | 1.4 mm |
| CP124 | 80 | 1.2 mm |
| CP125 | 80 | 1.4 mm |
| CP126 | 100 | 1.2 mm |
| CP127 | 100 | 1.4 mm |
| CP128 | 60 | 1.2 mm |
| CP129 | 60 | 1.4 mm |
| CP130 | 90 | 1.2 mm |
| CP131 | 90 | 1.4 mm |
| CP132 | 120 | 1.2 mm |
| CP133 | 120 | 1.4 mm |
| CP134 | 150 | 1.2 mm |
| CP135 | 150 | 1.4 mm |
| KingFiber CP200 E-Modulus 210 GPA | ||
|---|---|---|
| Product no. | Width (mm) | Thickness (mm) |
| CP210 | 50 | 1.4 mm |
| CP220 | 80 | 1.4 mm |
| CP230 | 100 | 1.4 mm |
| CP240 | 60 | 1.4 mm |
| CP250 | 90 | 1.4 mm |
Storage
Shelf life is 1 year when stored under cover, out of direct sunlight and protected from extremes of temperature.
Failure to comply with the recommended storage conditions may result in premature deterioration of the product or packaging. For specific storage advice consult KingKrete's Technical Services Department.
Health and safety
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs. Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal containers after use. Use in well ventilated areas and avoid inhalation.